Tree Planting and Maintenance
Buyer: University Of Edinburgh
£2,000,000
Open
Submission deadline: Jan 5, 2027, 12:00 PM UTC
| Status | Awarded |
|---|---|
| Estimated value | £162,155 |
| Submission deadline | Deadline not published |
| Published | Nov 24, 2026 |
| Buyer | University Of Edinburgh |
| Country | United Kingdom · Edinburgh |
| CPV code | 38540000 |
| Source | Find a Tender ↗ |
This notice is no longer open for submissions. The original remains available for reference.
| Awarded supplier / winner | Registration / LEI number | Country | Awarded contract amount | Award date |
|---|---|---|---|---|
| Merrow Scientific Ltd Surrey Technology Centre, 40 Occam Rd, Guildford, GU2 7YG | GB-FTS: 188574 | United Kingdom | £162,155 | Nov 24, 2026 |
Buyer: University Of Edinburgh
£2,000,000
Open
Submission deadline: Jan 5, 2027, 12:00 PM UTC
Buyer: Luminate Education Group
Value not published
Open
Submission deadline: Dec 23, 2026, 12:00 PM UTC
Buyer: Malmö universitet
SEK 1,700,000
Closing soon
Submission deadline: Nov 27, 2026, 10:59 PM UTC
Buyer: Sieć Badawcza Łukasiewicz - PORT Polski Ośrodek Rozwoju Technologii
Value not published
Closing soon
Submission deadline: Nov 26, 2026, 10:00 AM UTC
Buyer: Deutsche Forschungsgemeinschaft e.V.
Value not published
Open
Submission deadline: Dec 21, 2026, 08:00 AM UTC
Checked:
The original notice takes precedence. Its status and conditions can change after collection.
Market research has established that the technical requirements for these systems can only be met by Merrow Scientific Ltd, acting as the UK partner for Linseis Messgeräte GmbH.
Both internal research activity and external customers require measurement across the full temperature range of −50°C to 1,000°C using xenon flash technology. Linseis is the only manufacturer identified that can deliver this range.
The system can also achieve high vacuum levels at sub-ambient temperatures. This is particularly important for work down to −50°C, where it allows residual moisture to be effectively removed from the chamber. It also gives far greater control over the gas atmosphere surrounding the sample, supporting more consistent and reproducible measurement conditions.
The DSC offers very rapid heating rates and accurate heat capacity measurement, which is required to complement the LFA measurements. Its optical access allows the sample to be observed visually and opens the potential for spectroscopic analysis, such as Raman. This visual observation also strengthens the educational value of the technique.
In addition, the DSC uses a replaceable chip, providing a cost-effective and sustainable means of maintaining reliable operation. This is critical for both the internal research community and external customers.
Market research has established that the technical requirements for these systems can only be met by Merrow Scientific Ltd, acting as the UK partner for Linseis Messgeräte GmbH.
Both internal research activity and external customers require measurement across the full temperature range of −50°C to 1,000°C using xenon flash technology. Linseis is the only manufacturer identified that can deliver this range.
The system can also achieve high vacuum levels at sub-ambient temperatures. This is particularly important for work down to −50°C, where it allows residual moisture to be effectively removed from the chamber. It also gives far greater control over the gas atmosphere surrounding the sample, supporting more consistent and reproducible measurement conditions.
The DSC offers very rapid heating rates and accurate heat capacity measurement, which is required to complement the LFA measurements. Its optical access allows the sample to be observed visually and opens the potential for spectroscopic analysis, such as Raman. This visual observation also strengthens the educational value of the technique.
In addition, the DSC uses a replaceable chip, providing a cost-effective and sustainable means of maintaining reliable operation. This is critical for both the internal research community and external customers.