Compressed Air, Nitrogen and Vacuum Systems Maintenance
Buyer: University of Exeter
£750,000
Open
Submission deadline: Dec 21, 2026, 12:00 PM UTC
| Status | Awarded |
|---|---|
| Estimated value | £39,836 |
| Submission deadline | Deadline not published |
| Published | Nov 12, 2026 |
| Buyer | University of Exeter |
| Country | United Kingdom · Exeter |
| CPV code | 50712000 |
| Source | Find a Tender ↗ |
This notice is no longer open for submissions. The original remains available for reference.
| Awarded supplier / winner | Registration / LEI number | Country | Awarded contract amount | Award date |
|---|---|---|---|---|
| Intoheat Ltd 3 Oaktree Place, Manaton Close, Matford Business Park, Exeter, EX2 8WA exeter@intoheat.co.uk | GB-PPON: PNXR-5864-VJBN | United Kingdom | £39,836 | Oct 17, 2026 |
Buyer: University of Exeter
£750,000
Open
Submission deadline: Dec 21, 2026, 12:00 PM UTC
Buyer: APEX HOUSING ASSOCIATION
Value not published
Open
Submission deadline: Jan 11, 2027, 02:00 PM UTC
Buyer: Belfast City Council
£600,000
Open
Submission deadline: Jan 15, 2027, 12:00 PM UTC
Buyer: Centre Intercommunal d'Action Sociale (Cias)
€200,000
Open
Submission deadline: Dec 14, 2026, 03:00 PM UTC
Buyer: Southern Housing
£11,660,000
Open
Submission deadline: Jan 6, 2027, 05:00 PM UTC
Checked:
The original notice takes precedence. Its status and conditions can change after collection.
Supply, deliver and install 1no Daikin VAM 1500J c/w external enclosure located as per the design intend drawing. Ventilation system design to deliver 400 L/S based upon an occupancy of 50 at 8 L/S per person. Supply, deliver & install 2no 1500mm long attenuators on the supply air and return air Supply, deliver and install 4no 250mm 900mm long attenuators fixed to the exhaust and fresh air connections on the VAM. Supply and install 2no 250mm 1phase 3kw inline electric heater battery to the fresh air inlets onto the VAM unit Supply and install galvanised ductwork system generally as per design intent drawing, including big foot frame for Daikin VAM unit and external ductwork. Installation of return air grille and up to 50no 65mm black stainless steel louvred vents as below. Design, supply and install BMS control wiring to VAM unit and new occupancy sensor, connected to the existing BMS system. Update site system and graphics to operate new ventilation system based upon CO2/Temp & occupancy. Supply and install new power supplies to the VAM unit and 2no inline electric heater battery’s. Connection made to existing distribution board. Thermally insulate external ductwork and clad with black venture clad