SprosRadar
Find tenders
Find a Tender · 107457-2026

AP-MALDI UHR Imaging Source

Key facts

StatusAwarded
Estimated value£101,780
Submission deadlineDeadline not published
PublishedNov 12, 2026
BuyerUniversity Of Edinburgh
CountryUnited Kingdom · Edinburgh
CPV code38433100
SourceFind a Tender ↗
Open official notice
Status
Awarded
Estimated value
£101,780
Submission deadline
Deadline not published
Published
Nov 12, 2026
Buyer
University Of Edinburgh
Country
United Kingdom
CPV code
38433100
Source
Find a Tender

Contract outcome & evergreen alternatives

This notice is no longer open for submissions. The original remains available for reference.

Awarded supplier / winnerRegistration / LEI numberCountryAwarded contract amountAward date
KR Analytical Ltd
77 Forge Fields, Sandbach, CW11 3RN
sue@kranalytical.co.uk · +44 1270763471
GB-FTS: 188329United Kingdom£101,780Nov 11, 2026

Open tenders in this CPV category (CPV 38000000 · View CPV × country award matrix)

Checked:

The original notice takes precedence. Its status and conditions can change after collection.

Description

The University of Edinburgh is seeking to award KR Analytical Ltd the contract for the purchase of a MassTech Atmospheric Pressure Matrix Assisted Laser Desorption Ionisation Ultra High Resolution Source (AP-MALDI UHR).

Lots

  1. 1

    The MassTech AP-MALDI UHR is required to provide high-resolution tissue-imaging capability (5–20 µm) on the University's existing Thermo Scientific Orbitrap Exploris 240 and Orbitrap Stellar mass spectrometers. It is the only source identified as compatible with the existing instruments' ion interfaces, acquisition controls and operating software, enabling seamless integration with established workflows.
    The system provides the specialist functionality required for molecular tissue imaging, including controlled tissue scanning, a small laser spot, optical sample observation and synchronised data acquisition to facilitate the reconstruction of molecular images. Its interchangeable design also allows the Exploris 240 to retain its existing LC-MS functionality when the MALDI source is not in use.
    No alternative solution has been identified that meets the combined technical, compatibility and integration requirements of the proposed application. The MassTech AP-MALDI UHR is therefore considered the only currently identified solution capable of meeting the University's immediate requirements.

Public business contacts

Stuart Linton

slinton2@ed.ac.uk

+44 1316502759

Checked: