CeTPD Laboratory Information Management System
Acheteur: University of Dundee
250 000 £GB
Ouvert
Date limite: 11 déc. 2026, 12:00 UTC
| Statut | Attribué |
|---|---|
| Montant estimé | Montant non publié |
| Date limite | Date limite non publiée |
| Publié | 13 nov. 2026 |
| Acheteur | University of Dundee |
| Pays | Royaume-Uni · Dundee |
| Code CPV | 66519200 |
| Source | Find a Tender ↗ |
Cet avis n’accepte plus d’offres. L’original reste disponible à titre de référence.
Acheteur: University of Dundee
250 000 £GB
Ouvert
Date limite: 11 déc. 2026, 12:00 UTC
Acheteur: North East Combined Authority
Montant non publié
Ouvert
Date limite: 22 déc. 2026, 12:00 UTC
Acheteur: Department of Education
1 833 333,33 £GB
Ouvert
Date limite: 6 janv. 2027, 15:00 UTC
Acheteur: Commune de Saint-Julien-les-Villas
Montant non publié
Ouvert
Date limite: 16 déc. 2026, 12:00 UTC
Acheteur: Syndicat Mixte des Transports du Petit Cul de Sac Marin(SMT)
Montant non publié
Ouvert
Date limite: 16 déc. 2026, 12:00 UTC
Vérifié:
L’avis officiel fait foi. Son statut et ses conditions peuvent évoluer après la collecte.
The University's operational district heating network, compressed air systems, pressurisation vessels, chillers over 25kw and steam distribution systems engineering assets are encompassed by all the requirements of the HSE Pressure Systems Safety Regulations 2000 (PSSR). These regulations and the associated HSG ACOPS requires the University to offer its PSSR engineering assets for frequent inspection by an externally appointed competent person insurance inspector. The frequency of these insurance inspections varies for individual assets at inspection periodicities of 12, 24 and 48 months. The individual asset and its associated stored energy risk is assessed by the insurance company and the University is notified that the inspection type to be undertaken shall be either a Thorough inspection, Sub-Thorough inspection or a Working inspection.
The University's operational district heating network, compressed air systems, pressurisation vessels, chillers over 25kw and steam distribution systems engineering assets are encompassed by all the requirements of the HSE Pressure Systems Safety Regulations 2000 (PSSR). These regulations and the associated HSG ACOPS requires the University to offer its PSSR engineering assets for frequent inspection by an externally appointed competent person insurance inspector. The frequency of these insurance inspections varies for individual assets at inspection periodicities of 12, 24 and 48 months. The individual asset and its associated stored energy risk is assessed by the insurance company and the University is notified that the inspection type to be undertaken shall be either a Thorough inspection, Sub-Thorough inspection or a Working inspection.