Compressed Air, Nitrogen and Vacuum Systems Maintenance
Acheteur: University of Exeter
750 000 £GB
Ouvert
Date limite: 21 déc. 2026, 12:00 UTC
| Statut | Attribué |
|---|---|
| Montant estimé | 39 836 £GB |
| Date limite | Date limite non publiée |
| Publié | 12 nov. 2026 |
| Acheteur | University of Exeter |
| Pays | Royaume-Uni · Exeter |
| Code CPV | 50712000 |
| Source | Find a Tender ↗ |
Cet avis n’accepte plus d’offres. L’original reste disponible à titre de référence.
| Attributaire / titulaire | Numéro d’immatriculation / LEI | Pays | Montant du contrat attribué | Date d’attribution |
|---|---|---|---|---|
| Intoheat Ltd 3 Oaktree Place, Manaton Close, Matford Business Park, Exeter, EX2 8WA exeter@intoheat.co.uk | GB-PPON: PNXR-5864-VJBN | Royaume-Uni | 39 836 £GB | 17 oct. 2026 |
Acheteur: University of Exeter
750 000 £GB
Ouvert
Date limite: 21 déc. 2026, 12:00 UTC
Acheteur: Southern Housing
11 660 000 £GB
Ouvert
Date limite: 6 janv. 2027, 17:00 UTC
Acheteur: Department of Agriculture, Environment and Rural Affairs - DAERA
350 000 £GB
Ouvert
Date limite: 18 janv. 2027, 15:00 UTC
Acheteur: University Of York
280 000 £GB
Ouvert
Date limite: 23 déc. 2026, 10:00 UTC
Acheteur: River Clyde Homes
Montant non publié
Ouvert
Date limite: 8 janv. 2027, 12:00 UTC
Vérifié:
L’avis officiel fait foi. Son statut et ses conditions peuvent évoluer après la collecte.
Supply, deliver and install 1no Daikin VAM 1500J c/w external enclosure located as per the design intend drawing. Ventilation system design to deliver 400 L/S based upon an occupancy of 50 at 8 L/S per person. Supply, deliver & install 2no 1500mm long attenuators on the supply air and return air Supply, deliver and install 4no 250mm 900mm long attenuators fixed to the exhaust and fresh air connections on the VAM. Supply and install 2no 250mm 1phase 3kw inline electric heater battery to the fresh air inlets onto the VAM unit Supply and install galvanised ductwork system generally as per design intent drawing, including big foot frame for Daikin VAM unit and external ductwork. Installation of return air grille and up to 50no 65mm black stainless steel louvred vents as below. Design, supply and install BMS control wiring to VAM unit and new occupancy sensor, connected to the existing BMS system. Update site system and graphics to operate new ventilation system based upon CO2/Temp & occupancy. Supply and install new power supplies to the VAM unit and 2no inline electric heater battery’s. Connection made to existing distribution board. Thermally insulate external ductwork and clad with black venture clad