SprosRadar
Buscar licitaciones
Tenders Electronic Daily (TED) · 764868-2026

ESB Communication Tower Maintenence

Datos clave (Key Facts)

EstadoAdjudicada
Importe estimado1.800.000 €
Plazo de presentaciónPlazo no publicado
Publicado4 nov 2026
CompradorElectricity Supply Board ( ESB )
PaísIrlanda · Dublin
Código CPV50332000, 50330000, 50300000, 50331000, 64200000, 50334400, 50334110, 50334100
FuenteTenders Electronic Daily (TED) ↗
Abrir anuncio oficial
Estado
Adjudicada
Importe estimado
1.800.000 €
Plazo de presentación
Plazo no publicado
Publicado
4 nov 2026
Comprador
Electricity Supply Board ( ESB )
País
Irlanda
Código CPV
50332000, 50330000, 50300000, 50331000, 64200000, 50334400, 50334110, 50334100
Fuente
Tenders Electronic Daily (TED)

Resultado de adjudicación y licitaciones abiertas

Este anuncio ya no admite ofertas. El original sigue disponible como referencia.

Adjudicatario / ganadorNúmero de registro / LEIPaísImporte adjudicadoFecha de adjudicación
Surecom Network Solutions Ltd
Bothair Beri, Cahir, E21TF84
jim.sheehan@surecom.ie · 0868147509
IE-REG: 39871Irlanda1.800.000 €19 oct 2026
Obelisk Group
Unit 301 Northwest business park, Dublin15, D15HY92
lbehan@obelisk.com · 0874825141
IE-REG: 257021Irlanda1.800.000 €19 oct 2026
Global Rail Services Ltd
516a Grants Rise, Greenogue Business Park, Rathcoole, D24 FH56
tenders@globalrailservices.com · 014588540
IE-REG: 347033Irlanda1.800.000 €19 oct 2026

Licitaciones abiertas en este CPV (CPV 50000000 · Matriz CPV × país)

Comprobado:

Prevalece el anuncio oficial. Su estado y condiciones pueden cambiar después de la recopilación.

Descripción

ESBT owns and operates circa 330 tower sites countrywide. Each tower is to be maintained on an 18 month rotating schedule throughout the term of the contract. The country is divided into 9 zones with approximately equal quantities of towers contained within each zone. This is subject to change as new sites are built and added to the rotation. The highest scoring three Applicants, following the tendering process, will be admitted to the Framework Agreement. It is proposed that the Contract will include: Certify existing fall arrest as per manufacturers guidelines. Insert Fall Arrest System certification date and scaff tag on ladder at base. Carry out torque test on the towers bolts to tower suppliers guidelines Check all operator equipment is secure and adequately installed to suitable standard. Collect all required operator data on the tower as per ESBT checklist and ensure each piece of equipment is labelled and photographed. Inspect all aspects of the tower as per ESBT climbdown checklist (supplied). Climbing ladder checklist to be completed for the replacement to Latchway system. Towers dimensions including wooded pole check. Carry out weep hole test. Repair minor damage appropriately i.e superficial rust, lubricate fixtures etc. Aircraft Warning Light check. Electromagnetic Field Test. Weep hole test. Fall Arrest System certification cert. Test resistance (earth check) and continuity on Lightning protection system. Tower torque check. Climbdown report on customer equipment. Update extranet with customer equipment details. Project management and Health and safety. Confirm that existing risk assessments are correct. Site maintenance completion documents (including before and after photos, test certificates, inventory, fall arrest replacement details.

Lotes

  1. Lot 1

    ESBT owns and operates circa 330 tower sites countrywide. Each tower is to be maintained on an 18 month rotating schedule throughout the term of the contract. The country is divided into 9 zones with approximately equal quantities of towers contained within each zone. This is subject to change as new sites are built and added to the rotation. The highest scoring three Applicants, following the tendering process, will be admitted to the Framework Agreement. It is proposed that the Contract will include: Certify existing fall arrest as per manufacturers guidelines. Insert Fall Arrest System certification date and scaff tag on ladder at base. Carry out torque test on the towers bolts to tower suppliers guidelines Check all operator equipment is secure and adequately installed to suitable standard. Collect all required operator data on the tower as per ESBT checklist and ensure each piece of equipment is labelled and photographed. Inspect all aspects of the tower as per ESBT climbdown checklist (supplied). Climbing ladder checklist to be completed for the replacement to Latchway system. Towers dimensions including wooded pole check. Carry out weep hole test. Repair minor damage appropriately i.e superficial rust, lubricate fixtures etc. Aircraft Warning Light check. Electromagnetic Field Test. Weep hole test. Fall Arrest System certification cert. Test resistance (earth check) and continuity on Lightning protection system. Tower torque check. Climbdown report on customer equipment. Update extranet with customer equipment details. Project management and Health and safety. Confirm that existing risk assessments are correct. Site maintenance completion documents (including before and after photos, test certificates, inventory, fall arrest replacement details.

    3.150.000 €

Contactos profesionales públicos

esprocurement@esb.ie

www.esb.ie

Comprobado: